Get Help from a Highly Trained HVAC Technician Today
When the weather starts to change, you need to make sure your heating and air conditioning systems are in working order and ready to properly keep your home at a comfortable temperature. At Frasier’s Plumbing and Heating, Inc., we understand how frustrating it is when your HVAC system malfunctions, which is why we are here to assist you with our repair, maintenance, and installation services. Our well-trained technicians will make your job our top priority, no matter how complicated it is.
Call us today at (715) 804 0947 to schedule your service with one of our HVAC technicians in Minocqua.
We Repair & Install All Types of Systems for Customers
Although some homes use different heating or cooling systems than others, our HVAC technicians continue to stay up-to-date with new information about repair techniques for all sorts of units. Our team of professionals can correctly install and service your HVAC system to maintain the quality of your home.
Some of the services we provide to customers in Minocqua include:
- Heater replacement
- Routine heating maintenance
- Furnace or boiler repair
- Emergency AC repair
- Ductless Split AC system services
- Duct cleaning & installation
Professional Furnace Repairs & Tune Ups
Take care of your furnace with Frasier’s! Highly trained, experienced, and equipped with the best tools and equipment, our Minocqua furnace repair team can expertly diagnose and solve all types of common heating issues. From furnaces that blow only cold air to issues with weird sounds or smells, our team can help you find a solution in a timely manner so that you won’t be without heat for long. In addition to our furnace repair services, we also offer annual maintenance and tune up services designed to catch small problems, make necessary adjustments, and keep your furnace running optimally. Regular maintenance not only cuts down on the likelihood that you’ll need repairs, it also extends the life of your equipment, saving you money in the long run.
We Are Here to Serve You Around the Clock
Your next heating or AC issue won’t happen on your schedule, which is why you need to get in touch with our professionals to request the service you need to keep your system running smoothly. Even if your HVAC system shuts down in the middle of the night, we offer 24/7 emergency services to provide you with assistance. With emergency service comes unexpected costs, but with our financing options, you’ll be able to pay it off over time.
Your HVAC project is important to us, and our technicians will treat your home with the respect it deserves when they help with your heating or air conditioning problem.
Call (715) 804 0947 today to schedule your service with one of our professional heater and AC technicians in Minocqua.
Recent Jobs and Reviews in Minocqua, WI
Job Locations and Reviews
Completed annual prepaid maintenance on air conditioning system. Performed visual inspection of evaporator coil through access grille, noting moderate dust and dirt accumulation on heat exchanger fins requiring attention during next service interval. System operational at time of inspection.
Completed annual prepaid maintenance on gas furnace system. Performed comprehensive combustion analysis using diagnostic equipment, recording oxygen levels, temperature readings, and efficiency measurements to verify proper burner operation and system performance. Inspected blower motor assembly and squirrel cage fan, noting normal dust accumulation on blower wheel fins consistent with regular operation. All system components functioning within normal parameters.
Completed annual prepaid maintenance on furnace system. Performed comprehensive inspection of all components, tested combustion efficiency readings with digital analyzer showing acceptable oxygen levels at 7.2% and supply temperature at 90.4°F, verified proper airflow through ventilation system, and inspected ductwork and housing components. System operating within normal parameters with no deficiencies noted.
Performed annual inspection on original 1970s furnace, identifying multiple critical issues including short cycling, corroded burners and pilot assembly, broken gas valve vent line, aged motor, damaged filter, broken burner box gasket, and disconnected furnace exhaust duct. Recommended necessary repairs to restore safe operation; customer opted for comprehensive system evaluation by comfort advisor.
Responded to no-heat call at commercial rooftop unit serving front of house area. Diagnosed issue with thermostat scheduling function interfering with proper operation. Disabled scheduling feature to restore heating functionality. Customer requested installation of three new Wi-Fi compatible thermostats to replace existing units.
Performed annual furnace inspection and evaluated humidifier system. Discovered significant debris accumulation within the humidifier drum assembly, indicating prolonged lack of maintenance. Cleaned accumulated sediment from housing, replaced worn mesh filter material, and restored proper humidification functionality to improve indoor air quality and system efficiency.
Responded to callback for Nest thermostat power issues following boiler installation. Diagnosed missing resistors on zone board causing thermostats to lose power and require manual charging. Installed appropriate resistors per Taco manufacturer specifications, restoring continuous power to thermostats.
Performed annual prepaid maintenance on Weil-McLain boiler system. Diagnosed and repaired three issues: replaced non-functioning office thermostat, installed new expansion tank due to ruptured bladder, and replaced inducer motor that was drawing excessive current beyond manufacturer specifications. All repairs were completed and system is now operating within normal parameters.
Successfully replaced faulty limit switch with compatible OEM component on heating system. Performed comprehensive testing to verify proper operation and restored system to normal functioning condition.
Performed inspection on an aged Slant Fin boiler reported to be making noise, finding CO leakage from deteriorated heat exchanger and degraded antifreeze in system. Observed significant moisture damage and possible mold growth on surrounding infrastructure. Advised customer that heat exchanger replacement would be difficult/costly as manufacturer is out of business and recommended system cleaning, flush with new antifreeze, and potential replacement of original zone pumps and valves.
Completed annual inspection on 5-year-old furnace. Diagnostic testing revealed normal combustion readings (O2: 8.8%, CO: 9PPM, CO2: 6.3%) but identified flame sensor requiring replacement. Provided customer with replacement estimate.
Responded to callback for inoperative zone system causing temperature control issues. Diagnosed faulty zone control board as root cause of heating failure. Replaced defective board and verified proper operation of all thermostats and zone functionality, restoring normal heating system operation throughout the residence.
Performed annual inspection on residential furnace. Examined burner assembly and internal components which appeared to be in functional condition without visible damage. No concerning issues found; completed standard preventative maintenance service.
Completed installation of four thermostats per customer approval, including one Wi-Fi enabled Honeywell Home model (set to 78.7°F with current reading of 67°F) and three non-programmable thermostats. Verified proper operation of all units with one digital display showing current temperature of 68°F and time of 10:08.
Completed sold repair work by replacing the electrode and damper assembly as specified in the original estimate. Accessed property using provided lockbox code and executed all authorized work without identifying any additional issues.
Responded to no-heat emergency call for a 3-4 month old furnace system. Diagnosed issue as frozen condensate exhaust line, evident by significant ice formation at the PVC pipe outlet. Replaced the damaged frozen fitting to restore proper exhaust flow and system operation.
Diagnosed no heat issue in unit under 10 years old. Inspection revealed severely plugged burners with significant rust and debris accumulation in the heat exchanger manifold. Removed burner assembly, thoroughly cleaned ports and passages to restore proper gas flow, reinstalled components, and verified normal ignition sequence and heating operation.
Performed annual preventative maintenance on a 2-year-old Lennox furnace system. Inspected all components including gas connections, PVC intake/exhaust venting, electrical connections, and heat exchanger. System is properly installed with appropriate clearances in basement location and is operating within manufacturer specifications. No issues identified during service.
Successfully completed sold repair by replacing the Ultravation UV Bulb Light Assembly X8794 in customer's HVAC system. Removed old UV light and filter, then installed new components according to manufacturer specifications to restore proper air purification functionality.