Highly Trained Technicians Available to Service Your AC & Furnace Systems
During the hot summer or the cold winter months, you want to be sure your home’s heater and AC systems are working properly so you can maintain your family’s comfort. It can be inconvenient and frustrating when those systems malfunction.
At Frasier’s Plumbing and Heating, Inc., our Merrill HVAC technicians are extensively-trained to install, repair, and provide maintenance for heater and AC systems. We make your needs our top priority and are happy to help with all your heating and cooling issues no matter the size.
Our Merrill heating and AC services include:
- Furnace or boiler repair
- Heater replacement
- Routine heating maintenance
- Emergency AC repair
- Duct cleaning & installation
- Ductless Split AC system services
Call today at (715) 804 0947 to schedule a service with one of our heating and cooling technicians.
Professional AC Repair in Merrill
We know not every home uses the same cooling system. That’s why our Merrill AC repair technicians continue learning about different systems and the proper service and repair techniques for them. Having these systems correctly serviced from the start is important for maintaining your family’s comfort.
We can fix all types of common air conditioning problems, including:
- AC won’t turn on
- AC is leaking water
- AC is blowing warm air
- AC constantly turns on and off
- Your home is unusually humid
Merrill Heating Repair, Replacement & Maintenance
Is your furnace acting up? In Wisconsin, you can’t afford to go without a working furnace for long, so be sure to call Frasier’s Plumbing and Heating, Inc. at the first sign of a problem with your heater. At Frasier’s, our customers are important to us, and we make sure to treat you with the kindness and respect you deserve. Our Merrill furnace repair technicians will diagnose your heating system and provide you with clear explanations of the services that would meet your needs. We offer comprehensive repair, new installation, replacement, and tune-up services to keep you warm during the cold months.
Frasier’s Plumbing and Heating, Inc. Is Available for You Around the Clock
Not every heating or AC issue is going to happen on a set schedule. If your system stops working in the middle of the night, you can rest assured knowing that our technicians are available to provide emergency heating and AC repairs for your system. We also constantly run through different heating and cooling scenarios so we know how to offer you efficient service when you need it. Sometimes unexpected issues with your systems bring unexpected costs, which is why we offer financing options that allow you to pay over time.
For efficient and professional heater and AC services in Merrill, contact us online or call us at (715) 804 0947.
Recent Jobs and Reviews in Merrill, WI
Job Locations and Reviews
Responded to reported boiler fluid leak for recall inspection. Conducted thorough examination of all piping and connections in boiler area but could not replicate the leak or identify any active leaking points at time of service. Tested system antifreeze concentration, which measured at 45% and is within normal operating parameters. Advised customer to document any future leaks with photographs for further evaluation.
Responded to no-heat call on residential furnace system (2012 unit). Upon inspection, discovered heavily corroded burner assembly preventing proper ignition and heat production. Removed failed burners and installed new burner assembly, verified gas valve operation, tested all electrical connections and control board functionality. Cycled system through multiple heating cycles, confirmed proper ignition sequence, flame characteristics, and heat delivery to living space.
Responded to no heat call on residential boiler system from the 1970s-1980s. Gas service had been shut off by utility company due to safety concerns. Upon inspection, diagnosed failed gas valve on aging boiler unit. Replaced defective dual standing pilot gas valve with Resideo VR8300A4508 replacement part. Restored heat to residence and returned system to safe operating condition.
Conducted free estimate for residential duct cleaning system. Upon inspection, discovered aging HVAC equipment and identified water leaks originating from plumbing systems in basement area, with visible moisture damage evident on concrete flooring. Documented conditions with photos and provided comprehensive estimates for duct cleaning services and necessary repairs.
Diagnosed and repaired 7-year-old natural gas furnace with overheating condition. Cleaned secondary heat exchanger and reinstalled furnace properly to restore normal heating operation. System now functioning within manufacturer specifications with proper airflow and temperature rise.
Responded to no-heat call on Navien boiler system. Diagnosed gas leak at the venturi assembly. Inspected internal components and identified defective gas connection requiring replacement parts. Customer advised of findings and awaiting approval on repair estimate.
Inspected 10-12 year old Lars Mini Therm boiler with no heat complaint. Diagnostic testing revealed failed heat exchanger with significant deterioration. Recommended complete boiler replacement as repair is not cost-effective given the age of the unit and extent of damage.
Performed diagnostic inspection on furnace control system. Identified issues with humidifier components requiring attention. Service was incomplete due to scheduling constraints; arranged for follow-up visit to complete humidifier repair and install humidifier stat.
Completed repiping work to establish proper air separation within the hydronic system. Replaced failed components including drain valve, expansion tank, relief valve, and inducer motor capacitor, while installing new drain and purge valves for improved maintenance access. Retained functional autofeed/backflow preventer to maintain system integrity and pressure regulation.
Diagnosed system with 4-flash error code after customer's attempted DIY ignitor replacement. Inspection revealed faulty control board as root cause of heating failure. Removed and replaced defective circuit board, tested system operation, and verified proper ignition sequence and heat production.
Completed 119 annual maintenance service on boiler system. Discovered failing capacitor, poor air separation, and significant aging of internal components including heat exchanger fins showing corrosion. Diagnostic testing revealed high temperature readings (202°) with visible condensation issues. Multiple repair options and potential system replacement were discussed with customer.
Responded to no-heat call for 20-year-old hydronic in-floor heating system. Inspection revealed severely corroded burners and a loose, corroded igniter assembly. Provided customer with replacement options but no repairs were performed at this time.
Performed annual preventive maintenance on furnace per prepaid service agreement. Inspected blower wheel assembly which showed normal dust accumulation; unit functioning within specifications. All components checked and system operating correctly.
Diagnosed no heat condition on Broan-Nortex Global LP Furnace (Model MG1E056F1ABM1, MPN 1025402XL0357J) in 1995 mobile home. Inspection revealed loose thermocouple wires and failed ignitor. Replaced filter and ignitor, securing thermocouple connections to restore proper heating function.
Responded to no-heat service call on a 7-year-old residential furnace. Diagnostic testing revealed a failed pressure switch preventing system operation. Removed defective low pressure switch and installed replacement component. System now functioning properly with normal heating operation resumed.
Responded to no-heat service call for 13-year-old Distinctions furnace. Diagnostic testing revealed failed burners preventing proper temperature achievement. Removed and replaced damaged burner assembly with new components. System now operating within normal parameters and producing adequate heat.
Diagnosed 26-year-old boiler experiencing intermittent heating failure resulting in inability to maintain 70° temperature setpoint. Inspection revealed faulty pressure switch and electrical short in the control board system. Advised customer that immediate component replacement is possible but recommended full system replacement due to age and potential for cascading failures. Customer elected to proceed with comfort advisor consultation.
Successfully completed replacement of a faulty 24V LP gas valve (P/N: 0151M00027FK) and pressure switch (P/N: 0130F00646S) on a Goodman furnace system. Conducted comprehensive diagnostic testing with digital meter to verify proper electrical readings after installation. System now operating within manufacturer specifications.
Completed manufacturer warranty replacement of defective furnace with new unit. Post-installation combustion analysis was performed using UEi C161 Combustion Analyzer to verify proper operation, with readings showing normal combustion parameters (O2: 7.9-8.5%, CO: 10-17 PPM, CO2: 8.2-8.6%) for the propane system.