Call the Experts at Frasier’s Plumbing, Heating & Cooling!
Are you sick of your heating or cooling system giving you trouble? Whether it’s a lack of heat during a frigid Wisconsin winter or no air conditioning when the sweltering heat and humidity crank up the temperature, you need someone who can get your system fixed and get you back to living comfortably again. At Frasier’s Plumbing, Heating & Cooling, providing exceptional home repair and maintenance services is what we’ve done for the last century. When it comes to repair, replacement, or maintenance for your air conditioner or heater, nobody has been doing it for longer, and nobody provides you with a better customer experience.
Call the experts at Frasier’s Plumbing, Heating & Cooling at (715) 804 0947 today for all your heating and air conditioning repair and maintenance needs!
Let Us Handle Your Heating & Cooling Needs!
Frasier’s Plumbing, Heating & Cooling has been providing customers with the home services they need for over 100 years, and in that time we’ve learned that being the name customers trust involves not only being there to solve your problems, but being able to solve the problem you have. We have the tools, training, and equipment to handle any type of heating and cooling problem, large and small, and we service all different types of equipment. Whether you have an older system or the latest equipment, we can service it and keep it running at its best all year long.
Our complete range of services includes:
- Air conditioning & heating repairs
- Air conditioning & heating installations
- Heat pump services
- HVAC maintenance services
- Indoor air quality
- Duct cleaning
- Emergency heating & cooling services
Eagle River AC Repair
When it comes to your home, you expect nothing less than the best, and the best is what we make it our mission to deliver. Our carefully-selected Eagle River AC repair technicians are not only skilled, but friendly and will do everything they can to make your day brighter. We’re professional through every step of the way, and we’re respectful of your home, your time, and your budget. We want you and your family to be safe and comfortable, and we do whatever it takes to keep your home that way.
Give us a call if you notice any of the following AC problems:
- Air conditioner is blowing warm air
- Air conditioner won’t turn on
- Air conditioner is leaking condensation
- Air conditioner isn’t cooling your home evenly
- Your home feels more humid than usual
- Your energy bill has increased, but your home still isn’t cool
Heater & Furnace Repair in Eagle River
A working heater is an absolute necessity during the winter. Whether you’re looking for a reliable heating company to tune up your furnace in the fall or need a fast emergency heater repair, Frasier’s has you covered. Our Eagle River heater repair pros have the tools, training, and skill to ensure that your problems are resolved quickly so you can go back to being comfortable as soon as possible. We understand that a heating problem in winter is an urgent issue and that you want the problem to be resolved quickly the first time. We come to your home quickly, find the root of the problem, and then implement a quality solution that solves it for good. We’re even available for emergency services 24/7 for all our Partner Plan Members and 8am-10pm – 7 days a week for all non-members.
Contact Frasier’s Plumbing, Heating & Cooling today to schedule your AC or heater repair appointment in Eagle River.
Frasier’s Plumbing, Heating & Cooling has completed 20 jobs in Eagle River, WI between June 2026 and July 2026. The most recent job was on July 2, 2026.Recent Jobs and Reviews in Eagle River, WI
Eagle River, WI at a glance
Job Locations and Reviews
Responded to no cooling call on 25+ year old air conditioning system where outdoor fan was running but compressor failed to start. Diagnosed and replaced failed capacitor, then performed comprehensive leak check which revealed system was low on refrigerant. Recharged system to proper levels after confirming no active leaks. Unit tested and operational upon departure. Customer was also provided with quote for air handler replacement but declined at this time.
Responded to callback on recently installed AC unit that would not operate on first use. Diagnosed faulty thermostat as root cause of no cooling condition. Verified system charge and setup parameters using refrigerant manifold gauges, confirming proper refrigerant levels and pressures. Replaced defective thermostat and verified system operation, restoring cooling functionality to unit.
Responded to water leak complaint in furnace area. Diagnosed blocked condensate drain line causing water overflow. Successfully cleared obstruction from condensate line, restoring proper drainage and eliminating leak.
Completed annual prepaid preventative maintenance inspection on mini-split AC system. Inspected ceiling-mounted air handler unit, verified louver operation and airflow direction, and documented system condition with photos. All components operating within normal parameters with no deficiencies noted at time of service.
Completed annual preventative maintenance inspection on 3-year-old furnace system. All components operating within normal parameters with no deficiencies noted or repairs required at this time.
Responded to water leakage complaint on 5-6 year old mini split head unit. Upon inspection, identified improper pitch on condensate drain line causing water to back up and leak when unit was operating. Corrected drain line pitch to ensure proper drainage and resolved leaking issue.
Completed prepaid annual maintenance on furnace system. Found dirty blower wheel with significant dust accumulation, wear on ignitor, burners, and inducer motor requiring monitoring. Performed combustion analysis with readings showing O2 at 6.6%, CO at 15 ppm, and CO2 at 8.2%. Documented blower assembly condition and provided estimate for duct cleaning services.
Completed annual preventive maintenance inspection on AC unit #1. Inspected blower assembly and verified proper operation of all components. No deficiencies found; system operating within normal parameters.
Completed annual preventative maintenance inspection on Furnace #2. Performed comprehensive system evaluation including blower assembly inspection, with all components found operating within normal parameters and no deficiencies identified requiring corrective action.
Completed annual preventative maintenance inspection on furnace #1. Performed comprehensive system evaluation including blower assembly inspection and combustion analysis. All temperature differentials, oxygen levels, and carbon monoxide readings measured within normal operating parameters. No deficiencies identified during inspection.
Completed annual preventive maintenance inspection on AC unit #2. Performed combustion analysis and system diagnostics with all readings within normal operating parameters. No deficiencies found; unit operating properly.
Completed annual prepaid maintenance on residential boiler system. Performed comprehensive inspection of all components including burner assembly, heat exchanger, gas connections, and safety controls. Verified proper operation of gas shutoff valves and inspected copper supply lines for leaks or deterioration. Conducted combustion analysis using digital analyzer, confirming oxygen levels at 9.5% and stack temperature reading of 328.4°F, indicating efficient combustion within acceptable parameters. Inspected electrical connections and conduit. All systems operating within normal specifications with no deficiencies noted. Unit left in safe and proper working condition.
Completed annual preventative maintenance inspection on boiler system. Performed comprehensive system evaluation including inspection of expansion tank, copper piping connections, pressure relief components, and all associated fittings. All components found to be operating within normal parameters with no issues identified requiring immediate attention or repair at this time.
Responded to callback for furnace running continuously and not responding to thermostat commands, with reported burning rubber odor. Upon inspection, could not replicate the issue of unit running when thermostat was set to off position. Removed access panel and performed diagnostic testing on internal components. Isolated problem to either thermostat or integrated furnace control board. Provided customer with estimates for both thermostat replacement and control board replacement (Goodman Two-Stage HSI Integrated Furnace Control, White Rodgers model 50C51-707). Customer elected to proceed with thermostat replacement to resolve intermittent operation issue.
Responded to service call for gas line relocation for kitchen stove installation. Assessed existing gas piping configuration and determined that approximately one inch of repositioning would be required to accommodate new appliance placement. Provided detailed estimate for the gas line modification work.
Completed annual maintenance tune-up on furnace over 10 years old. Identified inducer motor producing abnormal noise and flame sensor showing wear, both requiring attention for continued reliable operation. Provided estimates for necessary repairs to address these components.
Completed annual maintenance tune-up on furnace over 10 years of age, including full system inspection and cleaning of blower assembly components. Identified abnormal noise coming from inducer motor and provided estimate for repair or replacement.
Completed annual tune-up on furnace over 10 years old. Identified noisy inducer motor, rusty burners, dusty blower assembly, and worn flame sensor during inspection. Performed combustion analysis showing O2 at 5.3% and CO2 at 8.9%, documented system conditions with photos, and provided estimate for recommended repairs.
Responded to no heat call on a 6-year-old Goodman furnace, model GMSS960603BNAA. Upon arrival, confirmed system was completely non-operational with no heat output. Performed diagnostic testing and determined the main control board had failed. Removed the defective printed circuit board and installed a new replacement control board. Restored power to the unit, verified proper system startup sequence, and confirmed furnace was heating normally with all safety controls functioning correctly.
Responded to no cooling call on 10+ year old system. Upon arrival, found thermostat calling for cooling but air handler completely non-operational. Inspected unit and discovered heavily soiled air filters restricting airflow and blower motor assembly. Documented condition of filtration media showing significant dust and debris accumulation, and photographed internal components including motor, wiring harness, and control board for diagnostic purposes.