Call the Experts at Frasier’s Plumbing, Heating & Cooling!
Are you sick of your heating or cooling system giving you trouble? Whether it’s a lack of heat during a frigid Wisconsin winter or no air conditioning when the sweltering heat and humidity crank up the temperature, you need someone who can get your system fixed and get you back to living comfortably again. At Frasier’s Plumbing, Heating & Cooling, providing exceptional home repair and maintenance services is what we’ve done for the last century. When it comes to repair, replacement, or maintenance for your air conditioner or heater, nobody has been doing it for longer, and nobody provides you with a better customer experience.
Call the experts at Frasier’s Plumbing, Heating & Cooling at (715) 804 0947 today for all your heating and air conditioning repair and maintenance needs!
Let Us Handle Your Heating & Cooling Needs!
Frasier’s Plumbing, Heating & Cooling has been providing customers with the home services they need for over 100 years, and in that time we’ve learned that being the name customers trust involves not only being there to solve your problems, but being able to solve the problem you have. We have the tools, training, and equipment to handle any type of heating and cooling problem, large and small, and we service all different types of equipment. Whether you have an older system or the latest equipment, we can service it and keep it running at its best all year long.
Our complete range of services includes:
- Air conditioning & heating repairs
- Air conditioning & heating installations
- Heat pump services
- HVAC maintenance services
- Indoor air quality
- Duct cleaning
- Emergency heating & cooling services
Eagle River AC Repair
When it comes to your home, you expect nothing less than the best, and the best is what we make it our mission to deliver. Our carefully-selected Eagle River AC repair technicians are not only skilled, but friendly and will do everything they can to make your day brighter. We’re professional through every step of the way, and we’re respectful of your home, your time, and your budget. We want you and your family to be safe and comfortable, and we do whatever it takes to keep your home that way.
Give us a call if you notice any of the following AC problems:
- Air conditioner is blowing warm air
- Air conditioner won’t turn on
- Air conditioner is leaking condensation
- Air conditioner isn’t cooling your home evenly
- Your home feels more humid than usual
- Your energy bill has increased, but your home still isn’t cool
Heater & Furnace Repair in Eagle River
A working heater is an absolute necessity during the winter. Whether you’re looking for a reliable heating company to tune up your furnace in the fall or need a fast emergency heater repair, Frasier’s has you covered. Our Eagle River heater repair pros have the tools, training, and skill to ensure that your problems are resolved quickly so you can go back to being comfortable as soon as possible. We understand that a heating problem in winter is an urgent issue and that you want the problem to be resolved quickly the first time. We come to your home quickly, find the root of the problem, and then implement a quality solution that solves it for good. We’re even available for emergency services 24/7 for all our Partner Plan Members and 8am-10pm – 7 days a week for all non-members.
Contact Frasier’s Plumbing, Heating & Cooling today to schedule your AC or heater repair appointment in Eagle River.
Frasier’s Plumbing, Heating & Cooling has completed 20 jobs in Eagle River, WI in December 2025. The most recent job was on December 23, 2025.Recent Jobs and Reviews in Eagle River, WI
Eagle River, WI at a glance
Job Locations and Reviews
Repaired significant antifreeze leak in boiler system by replacing punctured copper pipe in the laundry room loop. Installed four isolation valves on supply lines to provide better system control and maintenance access. Recharged system with 2.5 gallons of antifreeze after completing repairs.
Diagnosed and repaired 5-year-old furnace with no heat issue caused by broken J hook on exhaust pipe. Removed condensation from exhaust line, corrected pitch with proper leveling, and installed two new J hooks to provide adequate support for the exhaust system.
Completed installation of customer's humidifier as part of an ongoing HVAC service. The system is connected to the existing HVAC unit with proper ductwork. Additional work required to finish ductwork connections and complete electrical wiring on a future visit.
Diagnosed system failure on 10+ year old furnace with hydronic heating coil connected to outdoor boiler. Identified failed control board as root cause of non-functional blower motor. Removed existing damaged control board and installed new replacement unit, restoring proper blower operation and heat distribution throughout the home.
Responded to no heat complaint for 10-year-old garage boiler system. Diagnosed failed recirculating pump as primary issue. Removed defective pump, installed new replacement unit, and added F3 cleaner to system. Follow-up visit scheduled to flush cleaning solution and add 2.5 gallons of Alphi 11 glycol mixture.
Performed annual maintenance on 10-year-old natural gas furnace with no prior service history. Inspected blower wheel assembly and other system components, finding no major issues. Provided customer with preventive maintenance recommendations to extend equipment life.
Responded to no-heat emergency call for 19-year-old Armstrong Air ULTRA furnace. Diagnosed failed ignition system and replaced igniter assembly, cleaned flame sensor, and verified proper combustion. Reconnected thermostat Wi-Fi and confirmed system is now operating within normal parameters with stable heat output.
Responded to no heat complaint for 10+ year old furnace where indoor temperature had fallen to 41 degrees. Completed comprehensive system overhaul including replacement of blower motor, control board, flame sensor, spark igniter, and burners. Post-repair testing confirmed proper operation with heating restored to set point without issues.
Completed scheduled heat inspection for customer on Partner Plan. Performed comprehensive system testing using combustion analyzer, confirming optimal oxygen levels (9.9%), CO2 concentration (6.2%), and operating temperatures (88.8°F). All systems functioning within normal parameters with no issues requiring attention.
Replaced igniter gasket and bathroom zone pump while performing comprehensive heat exchanger cleaning. Addressed additional issues including cleaning plugged backflow and feed valve screens, freeing up check valve, and correcting improperly pitched exhaust pipe. System still experiencing intermittent ignition problems and fan operation irregularities; recommended follow-up service visit for further diagnostics.
Performed annual inspection on Trane XE90 furnace and identified numerous repair needs. Examined components in crawl space including plumbing fixtures and electrical connections. Provided repair estimates and replacement options to customer, who will contact LP company regarding regulator replacement.
Performed annual tune-up on 3-year-old Rheem single-stage system. Conducted combustion analysis with readings of O2 at 10.1%, CO at 17ppm, and CO2 at 7.1% at 85.4°F operating temperature. Inspected blower assembly for proper operation; found system functioning within normal parameters with no issues requiring correction.
Performed annual furnace inspection as scheduled. Examined blower wheel assembly which showed normal dust accumulation and wear consistent with regular operation. System functioning within normal parameters with no issues detected requiring immediate attention.
Responded to no heat/hot water call for 10-15 year old natural gas boiler. Diagnosed system with low pressure issue. Successfully restored heat by replacing water fill valve and properly pressurizing the system.
Responded to no heat call for a home at 32°F with non-functioning Nest thermostat. Diagnostic revealed low battery was preventing proper operation. Connected common wire to provide constant power supply to thermostat, resolving the issue and restoring heating function.
Completed replacement of boiler feed valve and installed new pressure gauge as specified in Luke V's estimate. Additionally, replaced expansion tank and relief valve under warranty, and added 3 gallons of Alphi 11 treatment solution. System tested and verified leak-free with all components functioning properly.
Performed annual furnace inspection on 19+ year old unit. Diagnostic testing showed combustion analysis readings of O2 at 12.0%, CO at 31 PPM, and CO2 at 5.1%. Visual inspection of blower assembly revealed dust accumulation. Recommended replacement of burners and ignitor due to age and condition, with immediate preventive maintenance advised to ensure continued safe operation.
Attempted replacement of faulty blower motor in furnace as per sold work estimate. Discovered replacement motor was defective straight from the box. Scheduled return visit to install new motor once replacement part is received.
Diagnosed no heat issue on 12-year-old furnace (37°F actual vs. 59°F setpoint) where the blower motor is showing signs of failure, confirmed through amp draw testing with readings of 340 on clamp meter and verification with tech support. Presented customer with repair and system replacement options given the unit's age.